How can I fix 'portX error' on GSE 672?
- RRoger ThomasSep 2, 2025
To fix the 'portX error' on GSE Scales, try reducing the baud rate (P200).
How can I fix 'portX error' on GSE 672?
To fix the 'portX error' on GSE Scales, try reducing the baud rate (P200).
What to do if GSE 672 Scales display 'WRONG CODE!'?
If your GSE Scales display 'WRONG CODE!', either the proper code must be entered, or the key must be pressed alone to view selections without making changes.
What causes 'prtyX error' on GSE 672 Scales?
The 'prtyX error' on GSE Scales can be caused by an incorrect baud rate (P200) or number of data bits (P201). Ensure these settings are correct.
What does 'Zero> Max.!' mean on GSE 672 Scales and how to fix it?
The 'Zero> Max.!' error on GSE Scales indicates that the zero value is greater than the maximum. You can use the key for subtracting off container weights, or apply this dead-load during the 'No Load?' prompt during calibration to permanently eliminate the offset.
How to resolve 'frmgX error' on GSE Scales?
To resolve the 'frmgX error' on GSE Scales, verify the baud rate (P200), the number of data bits (P201), or the parity setting (P202).
How to fix 'Under Load!' error on GSE 672 Scales?
To address the 'Under Load!' error on GSE Scales: * Reduce the load. * Check the load cell connections. * Ensure the sense jumpers are in place. * Verify the capacity selection P110 is correct. * Use information parameters, especially P61103 and P61104, to check the setup and input signal.
Why do GSE Scales say 'Tare> F.S.!'?
The 'Tare> F.S.!' error on GSE Scales most likely means the entered tare value was incorrect. Review and correct the tare value.
What to do if my GSE 672 display 'Over- Load!'?
If your GSE Scales are displaying an 'Over- Load!' error, use the same checks as you would for an underload situation. Reduce the load.
Details on the scale's die-cast aluminum enclosure and the load cell's installation procedure.
Information on the main board connectors and the layout and features of the scale's keypad.
Explanation of the functions performed by each key on the GSE Model 672 scale.
Description of the graphic LCD display and the various ports on the rear panel of the scale.
Details on enabling and configuring the Basic Weigh mode and its display styles.
Configuration of display styles (1, 2, 3), application menu, and calibration access.
Introduction to the APW Lookup mode and its associated function keys (Sample, Store, Rec/New, Entry, Setup).
Navigation through the APW Lookup configuration menus for sample, part number, and display settings.
Explanation of the setup menu structure, function keys, and parameter entries.
Detailed descriptions of APW lookup display styles (Style 1 and Style 2) and their parameter options.
Configuration of APW Style 3, setting display modes, and managing print menus and presets.
Guide to navigating the advanced setup menu, including time/date and mode access.
Instructions for configuring time/date, accessing setup mode, and using the application menu.
Step-by-step guide for performing sample and count operations in Basic Weigh mode.
Instructions for sample and count operations within the APW Lookup mode.
Procedures for storing, updating, recalling, and deleting part numbers in the APW Lookup.
Details on simple keypad sampling and auto-tare methods for APW and Basic Weigh.
Methods for accessing the calibration mode via APW Lookup or Basic Weigh modes.
Overview of available calibration methods and general notes for performing calibration.
Step-by-step instructions for performing a New Zero calibration on the scale.
Procedure for performing a span re-calibration without removing the test weight.
Instructions for calibrating without removing the current gross load.
Procedures for performing Only Zero calibration and resetting the A/D amplifier.
Steps for calibrating without test weights using known load cell output values.
Instructions for calibrating when more than one scale is enabled.
Information on National Type Evaluation Program (NTEP) standards for weights and measures.
Guide to accessing and configuring NTEP custom setup parameters for compliance.
Details on physical sealing methods and the scale's audit trail features for tamper evidence.
Explanation of OIML, Calibration, and Setup audit trails and how they are incremented.
How to view audit trail parameters and information on enabling OIML operation.
Lists and descriptions of common operational errors and setup mode error codes.
Details on various hardware-related error messages encountered during operation.
Error codes related to calibration failures and communication issues.
Further descriptions of communication error messages and their potential causes.