GPP Series User Manual
164
Description
<value> The available setting range, which is from
1 to (Points-1), is relevant to the actively set
period.
Example
:SEQUence2:TEMPlet:WIDTh 5
Sets the pulse width of Pulse as 5s for CH2.
Command
:SEQUence[1|2]:TEMPlet:WIDTh?
Function
Queries the pulse width of the actively set Pulse.
Example
:SEQUence2:TEMPlet:WIDTh?
Returns the pulse width of the actively set Pulse
for CH2.
Command
:SEQUence[1|2]:TEMPlet:STARt <value>
Function
Sets the sequential number of channel sequence
output templet to strat execution.
Example
:SEQUence2:TEMPlet:STARt 100
Sets the initial number of CH2 sequence output
templet as 100.
Command
:SEQUence[1|2]:TEMPlet:STARt?
Function
Queries the sequential number of channel
sequence output to strat execution.
Example
:SEQUence2:TEMPlet:STARt?
Returns to the initial number of CH2 sequence
output templet.
Command
:SEQUence[1|2]:MEMory:SAVE
{0|1|2|3|4|5|6|7|8|9}