REMOTE CONTROL
169
Command
: TRIGger:IN:SENSitivity? {D0|D1|D2|D3|D4}
Function
Queries the trigger sensitivity from the trigger input
of the specified data line.
Example
TRIGger:IN:SENSitivity? D0
Returns the trigger sensitivity from the trigger input
of D0 data line.
Command
:TRIGger:IN:SOURce {D0|D1|D2|D3|D4} ,
{CH1|CH2|CH3|CH4},{ON|OFF}
Function
Sets the controlled channel from the trigger input of
the specified data line.
Description
{CH1|CH2|CH3|CH4}
Any of the channels, CH1, CH2, CH3, CH4 is
available for controlled channel.
Example
:TRIGger:IN:SOURce D0,CH1,ON
Sets the controlled channel from the trigger input of
D0 data line as CH1.
Command
:TRIGger:IN:SOURce?{D0|D1|D2|D3|D4}
Function
Queries the controlled channel from the trigger
input of the specified data line.
Example
:TRIGger:IN:SOURce? D0
Returns the controlled channel from the trigger
input of D0 data line.
Command
:TRIGger:IN:TYPE
{D0|D1|D2|D3|D4},{RISE|FALL|HIGH|LOW|ST
ATE }
Function
Sets the trigger type from the trigger input of the
specified data line.