REMOTE CONTROL
155
Example
:SEQUence2:TEMPlet:SELect SINE
Sets the selected templet type as SINE for CH2.
Command
:SEQUence[1|2]:TEMPlet:SELect?
Function
Queries the actively selected templet type.
Example
:SEQUence2:TEMPlet:SELect?
Returns the actively selected templet type for CH2.
Command
:SEQUence[1|2]:TEMPlet:SYMMetry <value>
Function
Sets the symmetry of RAMP.
Description
<value> Ranges from 0 to 100.
Example
:SEQUence2:TEMPlet:SYMMetry 50
Sets the symmetry of RAMP as 50% for CH2.
Command
:SEQUence[1|2]:TEMPlet:SYMMetry?
Function
Queries the symmetry of the actively set RAMP.
Example
:SEQUence2:TEMPlet:SYMMetry?
Returns the symmetry of the actively set RAMP for
CH2.
Command
:SEQUence[1|2]:TEMPlet:WIDTh <value>
Function
Sets the pulse width of Pulse.
Description
<value> The available setting range, which is from
1s to (period 1s), is relevant to the actively set
period.
Example
:SEQUence2:TEMPlet:WIDTh 5
Sets the pulse width of Pulse as 5s for CH2.
Command
:SEQUence[1|2]:TEMPlet:WIDTh?
Function
Queries the pulse width of the actively set Pulse.