EasyManuals Logo

GW Instek GPP-4323 User Manual

GW Instek GPP-4323
200 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #123 background imageLoading...
Page #123 background image
REMOTE CONTROL
123
Output Commands
Command
:OUTPut[1|2|3|4][:STATe] <b>
Function
Turns the output on or off.
Description
<b>
0/OFF: Turn off the output
1/ON: Turn on the output
Example
:OUTPut:STATe ON
Turns on the output. of CH1
Command
:OUTPut[1|2|3|4][:STATe]?
Function
Queries the output state.
Example
:OUTPut:STATe?
Returns the output state of CH1.
Command
ALLOUTON
Function
Turns the channels output on
Example
ALLOUTON
Turns the channels output on
Command
ALLOUTOFF
Function
Turns the all channels output off.
Example
ALLOUTOFF
Turns the all channels output off.
Command
OUT<Boolean>
Function
Turns the output on or off.
<Boolean> : 0= off, 1=on

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GW Instek GPP-4323 and is the answer not in the manual?

GW Instek GPP-4323 Specifications

General IconGeneral
BrandGW Instek
ModelGPP-4323
CategoryPower Supply
LanguageEnglish

Related product manuals