124
Example
OUT1
Turns on the output
Command
:OUTPut[1|2|3|4]:OVP:STATe <b>
Function
Turns OVP protection on/off
Description
<b>
0/OFF:Turns OVP off.
1/ON:Turns OVP on.
Example
:OUTPut2:OVP:STATe ON
Turn on OVP on CH2.
Command
:OUTPut[1|2|3|4]:OVP:STATe?
Function
Queries the status of the OVP function.
Example
:OUTPut2:OVP:STATe?
Returns the status of the OVP function on CH2.
Command
:OUTPut[1|2|3|4]:OVP <value>
Function
Sets the OVP level.
Description
<value>
CH1 0.50-35.00V
CH2 0.50-35.00V
CH3 0.50-5.50V(GPP-4323)
CH4 0.50-16.50V(GPP-4323)
Example
:OUTPut2:OVP 10.05
Sets the OVP voltage to 10.05V for CH2.
Command
:OUTPut[1|2|3|4]:OVP?
Function
Queries the OVP voltage level.
Example
:OUTPut2:OVP?
Queries the OVP voltage level on CH2.