EasyManua.ls Logo

GW Instek GPP-4323 - Page 125

GW Instek GPP-4323
200 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
REMOTE CONTROL
125
Command
:OUTPut[1|2|3|4]:OCP:STATe <b>
Function
Turns OCP protection on/off
Description
<b>
0/OFF:Turns OCP off.
1/ON:Turns OCP on.
Example
:OUTPut2:OCP:STATe ON
Turn on OCP on CH2.
Command
:OUTPut[1|2|3|4]:OCP:STATe?
Function
Queries the status of the OCP function.
Example
:OUTPut2:OCP:STATe?
Returns the status of the OCP function on CH2.
Command
:OUTPut[1|2|3|4]:OCP <value>
Function
Sets the OCP level.
Description
<value>
CH1 0.05-3.50A
CH2 0.05-3.50A
CH3 0.05-1.20A(GPP-4323)
CH4 0.05-1.20A(GPP-4323)
Example
:OUTPut2:OCP 1.5
Sets the OCP voltage to 1.5A for CH2.
Command
:OUTPut[1|2|3|4]:OCP?
Function
Queries the OCP current level.
Example
:OUTPut2:OCP?
Queries the OCP current level on CH2.

Table of Contents