Description
ON|OFF||TOGGLE|POWER|CV|CC|CR|IND|
SER|PAR }
Enable output (ON): when the input signal of the
specified data line meets the trigger condition,
enable the channel output of the actively selected
controlled channel.
Disable output (OFF): when the input signal of the
specified data line meets the trigger condition,
disable the channel output of the actively selected
controlled channel.
Output Invert mode (TOGGLE): when input signal
of the specified cable line meets the set triggering
condition, invert the currently selected controlled
channel output.
Output Power mode (POWER): when input signal
of the specified cable line meets the set triggering
condition, set the currently controlled channel in
the power mode.
Output Load CV mode (CV): when input signal of
the specified cable line meets the set triggering
condition, set the currently controlled channel in
the load CV mode.
Output Load CC mode (CC): when input signal of
the specified cable line meets the set triggering
condition, set the currently controlled channel in
the load CC mode.
Output Load CR mode (CR): when input signal of
the specified cable line meets the set triggering
condition, set the currently controlled channel in
the load CR mode.
Output Individual mode (IND): when input signal of
the specified cable line meets the set triggering
condition, set CH1/CH2 in the individual power mode.