CONFIGURATION
105
UART Settings
UART Mode
Sets the UART mode or disables UART.
F-70
0 = Disable UART, 1 = RS232,
2 = RS485
UART Baud Rate
Sets the UART baud rate.
F-71
0 = 1200, 1 = 2400, 2 = 4800,
3 = 9600, 4 = 19200, 5 = 38400,
6 = 57600, 7 = 115200
UART Data Bits
Sets the number of data bits.
F-72
0 = 7 bits, 1 = 8 bits
UART Parity
Sets the parity.
F-73
0 = None, 1 = Odd, 2 = Even
UART Stop Bit
Sets the number of stop bits.
F-74
0 = 1 bit, 1 = 2 bits
UART TCP
UART transmission control protocol TCP
settings. This is used primarily for multi-unit
remote control, see page 168.
Note: Please refer to the TDK Genesys Series
user manual for the TDK control commands.
F-75
0 = SCPI, 1 = TDK (emulation
mode)
UART Address
(For TDK)
UART Address (For TDK). This is used to set
the address of a unit when using multi-unit
remote control, see page 168 for details.
Note: Please refer to TDK Genesys Series user
manual for more information on the UART
address.
F-76
0 ~ 31