EasyManua.ls Logo

GW Instek PSU 6-200 - Constant Current Mode; Protection Function

GW Instek PSU 6-200
196 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PSU Series User Manual
188
Constant Current Mode
Model
PSU
6-200
12.5-120
20-76
40-38
60-25
Line regulation
(*3)
mA
22
14
9.6
5.8
4.5
Load regulation
(*11)
mA
45
29
20.2
12.6
10
Ripple and
noise (*12)
r.m.s.
mA
400
240
152
95
75
Temperature
coefficient
ppm/ °C
100ppm/°C of rated output current, after a 30 minute
warm-up.
Protection Function
Model
PSU
6-200
12.5-120
20-76
40-38
60-25
Over voltage
protection
(OVP)
Setting
range
V
0.6 - 6.6
1.25 -
13.75
2 - 22
4 - 44
5 - 66
Setting
accuracy
V
0.06
0.125
0.2
0.4
0.6
Over current
protection
(OCP)
Setting
range
A
5 - 220
5 - 132
5 - 83.6
3.8 - 41.8
2.5 - 27.5
Setting
accuracy
A
4
2.4
1.52
0.76
0.5
Under voltage
limit (UVL)
Setting
range
0 - 6.3
0 - 13.12
0 - 21
0 - 42
0 - 63
Over
temperature
protection
(OHP)
Operation
Turn the output off.
Incorrect
sensing
connection
protection
(SENSE)
Operation
Turn the output off.
Low AC input
protection (AC-
FAIL)
Operation
Turn the output off.
Shutdown (SD)
Operation
Turn the output off.
Power limit
(POWER
LIMIT)
Operation
Over power limit.
Value
(fixed)
Approx. 105% of rated output power

Table of Contents

Related product manuals