PSU Series User Manual 
170 
Set the address of each slave to 
a unique address identifier  
7.  Multiple units can now be operated at the same 
time. See the programming manual or see the 
function check below for usage details. 
Serial link cable 
with RJ-45 
shielded 
connectors from 
PSU-232 or PSU-
485 connection 
kit 
Multi-Unit Function Check 
 
Invoke a terminal application such as Realterm. 
To check the COM port No, see the Device 
Manager in the PC. For WinXP; Control panel 
ā System ā Hardware tab. 
Below shows an example using the TDK 
GENESYS legacy commands. 
When using the TDK GENESYS legacy 
commands, each unit can be individually 
controlled using the unique address identifiers. 
For this function check, we will assume that the 
master unit is assigned to address 8, while a 
slave is assigned address 11.