Item S3100V2-26TP-PWR-EI S3100V2-16TP-PWR-EI S3100V2-8TP-PWR-EI
Total PoE output
power
370 W 250 W 125 W
Power consumption
(minimum hardware
and software
configuration)
20 W 20 W 16 W
Power consumption
(full hardware
configuration, all PoE
ports are supplying
power)
AC: 465 W
DC: 400 W
AC: 300 W
DC: 273 W
155 W
Max thermal output
AC: 1586.6265 BTU/h
DC: 1364.8400 BTU/h
AC: 1023.6300 BTU/h
DC: 931.5033 BTU/h
528.8755 BTU/h
Cooling system Built-in fans Built-in fans Built-in fans
Operating
temperature
0°C to 45°C (32°F to 113°F)
Relative humidity
(noncondensing)
10% to 90%
Fire resistance
compliance
UL60950-1, EN60950-1, IEC60950-1, GB4943
Chassis leakage
current compliance
UL60950-1, EN60950-1, IEC60950-1, GB4943
Table 16 S3100V2-TP-PWR-EI switches fan specifications
Item S3100V2-26TP-PWR-EI S3100V2-16TP-PWR-EI
S3100V2-8TP-PWR-EI
Fans 4 3 2
Airflow direction Left side to right side Left side to right side Left side to right side
Fan speed 8200 RPM 8200 RPM 6300 RPM
Max airflow 9.4 × 4 CFM 9.4 × 3 CFM 7.17 × 2 CFM
Max power
consumption
1.2 × 4 W 1.2 × 3 W 0.72 × 2 W
Min power
consumption
0.84 × 4 W 0.84 × 3 W 0.5 × 2 W
NOTE:
An S3100V2-TP-PWR-EI switch automatically disables the PoE function of all ports when the internal
temperature exceeds 65°C (149°F), and re-enables the PoE function of all ports when the internal
temperature drops under 60°C (140°F).
The DC power input and the AC power input on the S3100V2-26TP-PWR-EI and S3100V2-16TP-PWR-EI
switches can simultaneously work in redundancy mode.