10
Device Number = 0
Function Number = 0
Vendor Id = 0x1000
Device Id = 0xAC
SubVendor Id = 0x1000
SubDevice Id = 0x3000
Board Name = HBA 9400-16i
Board Assembly = 03-50008-15011
Board Tracer Number = SPB2726571
Physical Drives = 7
PD LIST :
=======
----------------------------------------------------------------------------
EID:Slt DID State DG Size Intf Med SED PI SeSz Model Sp
----------------------------------------------------------------------------
7:0 0 JBOD - 10.913 TB SATA HDD N N 512B ST12000NM001G-2MV103 U
7:1 1 JBOD - 7.277 TB SATA HDD N N 512B HGST HUS728T8TALE6L4 U
7:2 2 JBOD - 7.277 TB SATA HDD N N 512B HGST HUS728T8TALE6L4 U
7:3 3 JBOD - 7.277 TB SATA HDD N N 512B HGST HUS728T8TALE6L4 U
7:4 4 JBOD - 12.732 TB SATA HDD N N 512B ST14000NM0018-2H4101 U
7:5 5 JBOD - 7.277 TB SATA HDD N N 512B HGST HUS728T8TALE6L4 U
7:12 6 JBOD - 1.746 TB SATA SSD N N 512B INTEL SSDSC2KB019T8 U
----------------------------------------------------------------------------
EID-Enclosure Device ID|Slt-Slot No.|DID-Device ID|DG-DriveGroup
UGood-Unconfigured Good|UBad-Unconfigured Bad|Intf-Interface
Med-Media Type|SED-Self Encryptive Drive|PI-Protection Info
SeSz-Sector Size|Sp-Spun|U-Up|D-Down|T-Transition
Requested Boot Drive = Not Set
Upgrading the firmware of a storage controller
Perform this task to upgrade the firmware and BIOS driver of a storage controller.
Syntax
./storcli64 /ccontroller_id download file=x.bin
./storcli64 /ccontroller_id download bios file=x.rom
Parameters
controller_id: Specifies the controller ID.
x.bin: Specifies the name of the storage controller firmware.
x.rom: Specifies the BIOS driver of the storage controller.
Examples
# Upgrade a storage controller.
[root@localhost storcli]# ./storcli64 /c0 download