Page #528 background imageLoading...
Page #528 background image
22
Configuring the system to identify the new storage controller
After a replacement, storage controller consistency check might fail if RAID arrays have been built
by using the replaced storage controller. This is because RAID configuration information is saved
on both the storage controller and drives.
The failure might cause the controller to stop operating if the controller's boot mode is set to Stop
on Error. The server cannot identify the new storage controller and the BIOS displays Failed on the
Advanced > Driver Health > AVAGO EFI SAS Driver page.
To solve this issue, perform the following tasks:
1. On the BIOS setup screen, select Advanced > Driver Health > AVAGO EFI SAS Driver, and
press Enter.
2. Select the storage controller, and press Enter.
3. As shown in Figure 32 and Figure 33, enter C or Y as prompted.
Figure 32 Identifying a storage controller (1)