Create covigram
Covigrams are ideal for frequent or conditional actions that should be controlled and/or auto-
matically triggered. A covigram denes a scene, in which a dened trigger starts one or more
actions. Different triggers are possible for the same action(s).
Triggers and actions are dened via If … … Then …-logic functions. In the course of this, sev-
eral triggers are OR-linked, while several actions are AND-linked.
Basically three types of triggers can be dened:
– Time:
This allows a daily routine to be congured at a specic time or one/several weekday(s) to
be selected, when one/several action(s) is/are to be triggered at a specic time.
– Event:
This allows a device with a respective switching/operating state to be selected, which then
forms the trigger for one/several action(s).
A group cannot be dened as a triggering event.
– Play:
When selecting the manual trigger, one/several action(s) can be started exclusively by an
operation in the app.
Denable types of actions for the trigger are:
– Device:
One or several devices can be selected from all added devices and their switching/operating
state, which should be reached after the trigger, can be dened.
– Push notication:
An individually created text message can be written for one/several triggers, which appears
as a push message for all users in the app when triggered. Timely information can be helpful
in order to initiate a countermeasure if required.
Once the project has been handed over, the installer does not receive a push message any
more.
In the event that the app is not opened, the push message is additionally output on the end
device, if enabled.
– Partial:
If a zone is selected as an action, a heating zone can be controlled after triggering, for ex-
ample, a new temperature setpoint is received or another operating state is switched to.
In this way, many combinations are possible.
As an example, three tasks will be implemented one after another in one covigram each:
Example 1: Temperature warning (Figure 21):
Task: If the room temperature drops below 18 °C in the bedroom or children's room, a message
should be sent in order to check this actively and to initiate countermeasures if required.
To do this, press the red
button.
The editing page Covigramm opens. The title line under
is activated.
Give the covigram a name via the keypad and terminate the entry with the Return button.
Dene trigger
Press the
button under If … … .
The page for dening a trigger opens.
Select the type of trigger, in the example Event
.
The button of the trigger type is highlighted in red. All devices of the project are listed with
symbolic buttons and their name.
The display can be swiped to the left and right.