32/64 CMp | Technical data
Bosch Rexroth AB, RE 15409 Version 08.2022,
Table18:Electrical/technicaldataowsensors
SLSP 21 SLSP 22 SLSP 23
Operating voltage [V]
19-30 DC
Analogue current output [mA]
4-20
Measuring range [l/min]
0-50 0-100 0-200
Ambient temperature [°C]
-10 to 60
Storage temperature [°C]
-25 to 80
Medium temperature [°C]
-10 to 80
Protection
IP 67
Pressure rating [bar]
16
Pin connection Pin 1
+ Supply voltage L+
Pin 2
+ Signal (4...20 mA)
Pin 3
Supply voltage / -Signal
Pin 4
L-
Note! When installing this sensor you have to change parameter "MEDI" to OIL1.
Table19:Settings of ow sensors
Factory settings
User settings
SU7000 SU8000 SU9000
SP1 10.0 20.0 40.0
Factory settings
rP1 5.0 10.0 20.0
ImPS 0.1 0.1 0.1
ImPR YES YES YES
OU1 Hno Hno Hno
OU2 I I I
SP2 (FLOW) 40.0 80.0 160.0
rP2 (FLOW) 30.0 60.0 120.0
SP2 (TEMP) 62.0 62.0 62.0
rP2 (TEMP) 44.0 44.0 44.0
ASP (FLOW) 0.0 0.0 0.0
AEP (FLOW) 50.0 100.0 200.0
ASP (TEMP) -10.0 -10.0 -10.0
AEP (TEMP) 80.0 80.0 80.0
Din 2 +EDG +EDG +EDG
CGA 100 100 100
FOU1 OFF OFF OFF
FOU2 OFF OFF OFF
dST 0.0 0.0 0.0
P-n Pnp Pnp Pnp
dAP 0.6 0.6 0.6
rTo OFF OFF OFF
diS d2 d2 d2
Uni Lmin Lmin Lmin
SELd FLOW FLOW FLOW
SEL2 FLOW FLOW FLOW
MEDI H2O H2O H2O OIL 1
Fig. 29: Contact ow sensors
42591