RE 15409, Version 08.2022, Bosch Rexroth AB
Technical data | CMp 27/64
6.3 SLSP
6.3.1 Pressure sensors
Function
Sensor type 01, 02 and 03 includes a 10, 250 or 400 bar pressure sensor,
minimess adaptor and electrical connector.
Type 01 — 10 bar sensor - case pressure measurement
Type 02 — 250 bar sensor - charge pressure measurement
Type 03 — 400 bar sensor - work pressure measurement
Table 11: Electrical data, pressure sensors
Pressure range type 01 0…10 bar
type 02 0…250 bar
type 03 0…400 bar
Supply voltage Ub 16…36 VDC
Output signal 4-20 mA
Max load (ohm) (Ub-8.5 V)/21.5 mA
Protection class IP65
Connector 4-pole M12 connector
Pin connection Pin 1 +Ub
Pin 2 signal output
DD00078643
Fig. 19: Pressure sensor, type 01, 02, 03
Fig. 20: Electrical symbol pressure sensor
Table 12: Mechanical data, pressure sensor
Connection (sensor) G 1/4
Connection (adaptor) M16 x 2 "minimess"
DD00078645