28/64 CMp | Technical data
Bosch Rexroth AB, RE 15409 Version 08.2022,
Function
Sensor type 11 includes a 30 mm temperature sensor and electrical connector.
The sensor can be used to measure the drain temperature in Hägglunds MA, VI
motors and pumps with an adapter.
Sensor type 12 includes a 60 mm temperature sensor and electrical connector.
The sensor can be used to measure the drain temperature in Hägglunds CB, CBp
and CBm motors.
Sensor type 13 includes a 30 mm temperature sensor, adaptor and a electrical
connector. The sensor can be used to measure the drain temperature in Hägglunds
CA motors.
6.3.2 Temperature sensors
DD00078674
Fig. 21: Temperature sensor, type 11, 12,13
Type 11 Type 12 Type 13
Table 13: Electrical data
Temp range 0...100 °C
Supply voltage Ub 10…30 VDC
Output signal 4-20 mA
Max load (ohm) (Ub-7.5V)/22 mA
Protection class IP65
Connector DIN 43650 (Hirschman)
Pin connection Pin 1 +Ub
Pin 2 signal output
DD00078677
Fig. 22: Electrical symbol temperature sensor