75
Installation
Before starting
Operation
Screen block
diagram
Function setting Program System setting Specifications
Parameter Setting range Default
Channel#n control signal relay
0 - 32 0
Channel#n control signal delay
0 - 9999 S 0 S
Channel#n sensor disconnection relay
0 - 32 0
Channel#n sensor disconnection holding time
0 - 9999 M 0 M
Channel#n ascending section relay
0 - 32 0
Channel#n ascending section offset
Channel #n EUS(0% - 100%) 0 ℃
Channel#n holding section relay
0 - 32 0
Channel#n holding section ON time
0 - 9999 M 0 M
Channel#n descending section relay
0 - 32 0
Channel#n descending section offset
Channel #n EUS(0% - 100%) 0 ℃
Channel#n DI signal relay
0 - 32 0
Channel#n DI signal operation time
0 - 9999 S 0 S
Channel#n wait relay
0 - 32 0
Channel#n wait holding time
0 - 9999 S 0 S
Channel#n constant-value signal relay
0 - 32 0
Channel#n constant-value signal setting time
0 - 9999 M 0 M
Channel#n program relay
0 - 32 0
Channel#n program setting time
0 - 9999 M 0 M
Example of relay operation state by temperature ascending/holding/descending setting of setting value(SV).
Example of relay operation state with ascending section setting temperature(-10 ℃), holding section setting
temperature(2M), and descending section setting temperature(+20 ℃).
RELAY
RELAY
RELAY
Temperature
ascending
Temperature
Holding (3M)
Temperature
Descending
Temperatur
Holding
sections
Ascending
Holding setting
= 2M
Descending
6. DI signal
- Screen to set relay and operation time for all DI signals
7. WAIT
- Set relay and holding time for wait signal.
8. Constant value
- When a constant-value operation is completed, the relay is ON for defined time.
9. Program
- When a program operation is completed, the relay is ON for defined time.
Fig. 130) DO - Ascending/Holding/Descending