Programmable Temperature & Humidity Controller
80
▶Memory
Displays used/free space of internal memory. Initialize error
history. (It can't operate when it is being saved)
Displays used/total space of SD card memory.
If initialized, data can't be recovered so send
it to an SD card before.
Caution
▶Indicator
- Screen to set indicators on constant-value and program operation screens.
- Up to 32 indicators can be selected. Up to 16 of them can be displayed in 1 screen, and tap them to
switch the touch screen.
1. Tap a cell to display in the indicator table above.
2. Select a type of indicator.
1. Ch.1 use mode and Ch.2 use mode
- Control -> Use as Control mode; Hide -> The channel is not used.(Both channels can't be hidden at the same time).
- If one channel is set to Control and the other is set to Hide, 1 channel operation screen is displayed.
2. Control mode
- Concurrent control : 2 channels are controlled with 1 operation signal.
- Individual control : Channels are individually controlled. (If a channel is set to Hide, it switches to the individual control).
Fig. 137) Memory screen
Fig. 138) Indicator Fig. 139) Indicator setting
Fig. 140) Indicator display