3 - Description
40
2. 1. 4. 07 Speed Driving speed
2. 1. 4. 08 Volume sprayed Readouts for Volume sprayed in currently active register
2. 1. 4. 09 Area sprayed Readouts for Area sprayed in currently active register
2. 1. 4. 10 Active boom size Active boom size including end nozzle
2. 1. 4. 11 Pressure Displays spray pressure if sensor is fitted
2. 1. 4. 12 Fan speed Displays Twin fan speed if sensor is fitted
2. 1. 4. 13 Wind Speed Displays wind speed if sensor is fitted
2. 1. 4. 14 Pendulum lock status Displays reading of pendulum lock sensor if fitted
2. 1. 4. 15 Pendulum unlock status Displays reading of pendulum unlock sensor if fitted
2. 1. 4. 16 Dynamic centre position Displays Dynamic centre position sensor if fitted
2. 1. 4. 17 Spray pump rev Displays revolutions if sensor is fitted
2. 1. 4. 18 Extra sensor 1F Readout from extra sensor 1 frequency
2. 1. 4. 19 Extra sensor 2F Readout from extra sensor 2 frequency
2. 1. 4. 20 Extra sensor 3A Readout from extra sensor 3 analogue
2. 1. 4. 21 Extra sensor 4A Readout from extra sensor 4 analogue
2. 1. 4. 22 Voltmeter Displays system voltage. Useful when fault finding
2. 1. 4. 23 Agitation Agitation valve opening
2. 1. 4. 24 RinseTank content RinseTank calculated content
2. 1. 4. 25 Slant angle Headland assist angle sensor
2. 1. 4. 26 Boom height Headland assist height sensor
2. 1. 4. 27 Air pressure Displays compressor air pressure if sensor is fitted
2. 1. 4. 28 Reserved R R
2. 1. 4. 29 Reserved R R
2. 1. 4. 30 Reserved R R
2. 1. 4. 31 Reserved R R
2. 1. 4. 32 Reserved R R
2. 1. 4. 33 Nozzle size flow at 3 bar Actual flow and pressure scaled to flow at 3 bar
2. 1. 4. 34
2. 1. 4. 35
2. 1. 4. 36
2. 1. 4. 37 PF bus + Voltage on PrimeFlow databus +
2. 1. 4. 38 PF bus - Voltage on PrimeFlow databus -
2. 1. 5 Show ESC softkey to leave ISOBUS terminal can have a separate ESC key or use an ESC softkey
2. 1. 5. 1 Show ESC as softkey Choose this to show ESC key as softkey on ISOBUS terminal
2. 1. 5. 2 Do not show ESC as softkey Choose this if ISOBUS terminal has a separate ESC key.
2. 2 AUTO functions AUTO functions
2. 2. 1 Reserved Reserved Reserved Reserved
2. 2. 2 Dual Line To set up lower and upper trigger limits for the operation of line A and line B
2. 2. 2. 1 Lower pressure level Key in pressure level to switch Dual Line to smaller nozzles
2. 2. 2. 2 Upper pressure level Key in pressure level to switch Dual Line to bigger nozzles
2. 2. 3 AutoAgitation select level Powerful or soft no Agitation
2. 2. 3. 1 Agitation switch Switch increase or decrease agitation
2. 2. 3. 2 Powerful AutoAgitation Recommended for powder
2. 2. 3. 3 Soft AutoAgitation Recommended for liquid chemical
2. 2. 3. 4 Fixed agitation Valve is positioned
2. 2. 3. 5 No agitation Never use if sedimentation occurs. Recommended for liquid fertilizer.
2. 2. 4 AutoAgitation fixed level Key in position of agitation valve for FluidBox key and fixed level
2. 3 VRA / Remote control Variable Rate Application by RS232 Auto Section Control
2. 3. 1 VRA / Remote control disable Variable Rate Application / Remote control disabled. Dish icon disappears
2. 3. 2 VRA / Remote control enable by RS232 data port control enabled. Dish icon will be shown
2. 4 Select next UT in tractor When tractor has 2 terminals select the next UT
2. 4. 1 Select next UT in tractor When tractor has 2 terminals select the next UT
Menu Number Menu Name Help Text in Display