Installation instructions, only for experts p. 28/48
Activating/deactivating the foil sensor
If an infrared heat plate is connected to an additional output, the P-ISX-FF foil sen-
sor must be used. The foil sensor must be activated. Perform the following steps:
1. Open the technician menu (see 26).
2. Turn the top knob to the additional output symbol (position B – see point
9.2 on page 30).
The additional output symbol lights up.
In the top display, “SEnF” appears.
In the bottom display, “OFF” appears.
(“OFF” means that the foil sensor is deactivated.)
3. Turn the bottom knob to the right.
In the bottom display, “On” appears.
The foil sensor is activated.
Setting the fan operating mode
The fan can either be regulated or switched on and off. The dimmer switch func-
tion for the fan is activated as standard. If you wish to deactivate the dimmer
switch function for the fan, perform the following steps:
1. Open the technician menu (see 26).
2. Turn the top knob to the fan symbol (position D – see point 9.2 on page 30).
The fan symbol lights up.
In the top display, “FAn” appears.
In the bottom display, “On” appears.
(“On” means that the dimmer switch function is activated.)
3. Turn the bottom knob to the left.
In the bottom display, “OFF” appears.
The dimmer switch function for the fan is deactivated.