Instructions for installation and use p. 48/48
Thermal safety
Heater sensor with excess temperature fuse (139 °C shut-off temperature)
Adjustable automatic heating period (6 h, 12 h, 18 h, 24 h)*
Optional single-sensor mode or two-sensor mode
Connection cables
Power supply cable: min. 5 x 2.5 mm²
Heater supply cable (temperature-resistant up to 150 °C):
min 2.5 mm²
Sensor wires (temperature-resistant up to 150 °C): min 0.5 mm²
Light wire: min. 1.5 mm²
Fan wire: min. 1.5 mm²
* EN 60335-2-53 species a heating time limitation of 6 h for saunas for private
use. For saunas in hotels, apartment blocks and similar locations, a maximum
heating period limit of 12 hours is permissible. Extending the heating period
limit to 18 hours or 24 hours is only permitted in public saunas.