Capture Sequence
This feature functions in the same manner as an interval timer and only works in conjunc-
tion with a motor or winder driven camera model except in the case of the Pinhole setting
where it is the only way of controlling such exposures (see later section for full details).
Initial delay: Controls the amount of time required to elapse before the first exposure.
Delay: Controls the amount of time required between each exposure.
Count: Controls the total number of exposures required.
Exposure Time
This setting should be changed for cable-free exposure times longer than 1/8 second, ensur-
ing that it matches the set shutter speed/exposure time on the camera/lens. The settings
range from 1/8 second to 32 seconds (1/8 second is the default setting). “< 1/8” as seen on
the menu list means ‘exposures no longer than 1/8 second’. The ELD also has a “Bulb” setting.
Shutter Delay
There can be differences in the amount of time required in preparation (raising the mirror,
opening/closing the shutter etc) for digital capture between various camera models. This
corrective feature adjusts the time a little to ensure the image is read out from the sensor.
The normal setting is Default and should only be changed if problems are encountered.
500
Forusewith500C/CM,501C/CMand503CX/CXi/CWmodels.
• Makea500 setting.
200
Forusewithmodied202,203and205modelstogetherwithF-lenses/CF-lensesin
F-mode.(Onlythesethreemodelscanbemodiedforcable-freecompatibilitywith
theCFV/503CWD.PleasecontactyourHasselbladdealerforfurtherinformation)
• Makea200 setting.
• AFlash sync input cable should not be used.
• Allexposurestimes,includingtheBsetting,functioncorrectlywithouthavingtoalterthe
“Exposure Time” setting.
• Donotuseawinderatrapidsequencesetting.
SWC
Forusewiththe903SWCand905SWCmodels(notrecommendedforcriticaluse).
• MakeanSWC setting.
PLEASE NOTE: Due to the mechanical design of the SWC, pressing the exposure release button too
slowly may cause a faulty capture with a magenta cast. Either press the button much more distinctly
or alternatively change the setting from SWC to Flash sync and use the Flash input sync cable to
connect the lens to the CFV.
Flash sync
Forusewithun-modied200seriesmodels(togetherwithC-lensesinC-mode),a
FlexBodyorviewcamerasttedwithaHasselbladadapter.
• MakeaFlash sync setting.
• AFlash sync input cable should be used.
• Allexposurestimes,includingtheBsetting,functioncorrectlywithouthavingtoalterthe
“Exposure Time” setting.
• Donotuseawinderatrapidsequencesetting.
Note
Although the 903SWC and 905SWC
models work in conjunction with a CFV,
the combination is not recommended
for critical work.
The Biogon 38 lens was designed for
film use where the unusually close prox-
imity of the lens to the film plane was
of no consequence. However, digital
sensors and their protective filters make
very different demands on the angle
and travelling distances of the periph-
eral rays exiting the rear lens element.
Gradual unsharpness consequently
occurs towards the edges of the frame,
particularly noticeable with flat subjects
(typically copying situations, 90º shots
against building façades, etc) though
these effects will be naturally less ob-
vious with more three-dimensional
subjects. Slight green and magenta
casts are also caused, though these can
be removed digitally in Phocus.

Table of Contents

Other manuals for Hasselblad 503CW

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hasselblad 503CW and is the answer not in the manual?

Hasselblad 503CW Specifications

General IconGeneral
Camera TypeMedium format SLR
Exposure ModesManual
FocusManual focus
Lens MountHasselblad V mount
Shutter TypeFocal-plane shutter
Flash Sync1/90 sec
MeteringExternal metering required
ViewfinderInterchangeable viewfinders (waist-level, prism)
Shutter Speed1 sec to 1/500 sec, Bulb
Flash Sync Speed1/90 sec