1B30E, 1B50E / 02 - Rev. 01 Faults
HATZ
83Manual
Flashing signal Possible causes Remedy Chapter
7
Area affected:
Fuel pump, glow
plug, injection
pump
Cabling is faulty. Check the cabling.
Fuel pump, glow
plug or injection
pump is faulty.
Contact HATZ ser-
vice.
8
Area affected:
Speed sensor
system
Cabling to the
crankshaft speed
sensor is faulty.
Check the cabling.
Crankshaft speed
sensor is faulty.
Contact HATZ ser-
vice.
Engine speed is
impermissibly high.
Contact HATZ ser-
vice.
9
Area affected:
Control unit
Cabling to the con-
trol unit is faulty.
Check the cabling.
Faulty control unit. Contact HATZ ser-
vice.
9.3 Emergency hand start
The series engine is equipped with an electric start mechanism. An emer-
gency hand start system that can be used to start the equipment by hand
can be installed additionally as an option. An emergency hand start should
only be performed if an electric start is not possible, e.g. when the battery is
weak.
This chapter contains the following subchapters:
Safety notes
Prerequisite for performing an emergency hand start
Performing tests
Emergency hand start with recoil start

Table of Contents