EasyManua.ls Logo

HellermannTyton M-BOSS Compact - Software Errors; Organiser Unit Errors

HellermannTyton M-BOSS Compact
53 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
GBDE
Operating instructions • M-BOSS Compact • 06-2020 • v02 • 544-12020
Troubleshooting
21
7.3 Software errors
Error Cause Remedy
Shifted type face Incorrect embossing coordinates
Check the embossing coordinates and correct if
necessary
Wrong embossed text on the marker Wrong link to the Excel table Check and re-link the Excel table
7.4 Organiser unit errors
Error Cause Remedy
The device stops or does not start up Open the organiser unit Close the organiser unit
Red status lamp flashing rapidly Organiser unit is blocked
Open the organiser unit, remove the blockage,
close the organiser unit
The device stops without finishing the em-
bossing job, the status lamp is red
The organiser unit was not reset before the
embossing job
Open the organiser unit, empty any filled boxes,
close the organiser unit

Table of Contents