The table below lists the allowed values for each of the configuration options.
No.
Option
Brief Description
Allowed
values
1
NUMBER OF ZONES
Set number of zones.
*Size of
controller
2
NUMBER 24HR STARTS
Set number of Daily automatic starts.
000-064
3
NUMBER WEEKLY
STARTS
Set number of Weekly automatic starts.
000-064
4
SKIP DAY STARTS
Set number of days to miss before auto start
activated again.
001 - 032
5
CURRENTLY NOT IN USE
6
NUMBER OF PROG
Set number of programs.
001-028
7
USE RAIN GAUGE
Rain gauge connected.
000/001
8
MANUAL PERCENT
Manual percentage adjustment of irrigation
programs
000/001
9
INPUT 1 USE
Controller suspends irrigation programs or
permanently stops irrigation programs.
000-002
10
INPUT 1 MESSAGE
Display Low Tank instead of Suspend or Stop.
000/001
11
AUTO ENABLE OPTION
Use ‘Disable Automatic Startsfacility
000/001
12
CURRENTLY NOT IN USE
13
ZONE INFO
Turn Zone Information display on /off
000/001
14
CONFIG PROGRAM
Allows zones within a program to be changed.
000/001
15
PROGRAM PERCENT
Increase or decrease an irrigation program run
time by a specified percentage
000/001
16
USE NAMES
Program name displayed when the program is
running.
000/001
17
NUMBER OF CYCLING
STARTS
Set the number of cycling starts required, i.e.
the cycling of programs between specified times
of the day.
000-032
18
NUMBER FLUSH FILTERS
See Backflush Manual
N/A
19
PRIORITY FLUSH
See Backflush Manual
N/A
20
PARALLEL PROGRAMS
Specify the maximum number of programs that
can be run in parallel.
000-006
as
standard
21
PARALLEL MANUAL
STARTS
Specifies the maximum number of zones that
can run in parallel whilst an irrigation program is
running.
000-004
22
CURRENTLY NOT IN USE
23
CURRENTLY NOT IN USE
24
ENG OPTION ENABLE
See Engineering Options Manual
N/A
25
GSM LAN
See GSM Manual
N/A
26
GSM LAN RESET
See GSM Manual
N/A
27
CURRENTLY NOT IN USE
28
NUMBER OF FLOW
METERS
Specify a flow meters is attached to the
controller.
000-001
as
standard
29
FLOW TEST ENABLED
Send a text alert if zone flow falls outside of its
specified flow volume range.
000/001
30
ADVANCE LO FLOW
Advance to the next zone if low flow fault
detected.
000/001
Y/N
31
ADVANCE HI FLOW
Advance to the next zone if high flow fault
detected.
000/001