Zones can be assigned to a group on theZONE CONFIGscreen.
The adjustment will be applied pro-rata for each zone within the group. For example, if a group has 2 zones,
zone 1 set to run for 6 minutes and zone 2 to run for 10 minutes. If the percentage adjustment is set for 50%,
then zone 1 will run for 3 minutes and zone 2 for 5 minutes.
Likewise, if the percentage adjustment is set to 200%. Then in example above, zone 1 would run for 12
minutes and zone 2 would run for 20 minutes.
WARNING: Leave the percentage value at 100% for programs to have their normal
run time. If the percentage is at 0%, the irrigation program will not run.
48. Back Up Prog
Set this option from 001 to 004 to specify the number of programs that can be delayed if program run times
overlap.
If a program is already running and another program is due to start and this option has been set, then the
second program will not start until the first program has finished. A maximum of 4 programs can be delayed.
If this option is not set then any overlapping programs will not run.
51. Display Current
Set this option to 001 to display the current on the run time page. .
52. Extra Info
Set this option to 001 to displayEXTRA INFOin the Main Menu.
This screen displays the controller pump start current and the status of any sensors if they are connected.
58. Flow Log Rate x10S
Enter the number seconds to be multiplied by 10, to wait before flow rate is measured. For example if this
option is set to 10, then the flow rate will be measured every 100 seconds.
b. Program Options
This option allows you to specify the number of zones in a program, the number of zones to run in parallel
and to specify zone run times in hours and minutes.
Select PROG OPTIONSfrom the Options Menu.