Enter the number of the program you want to edit. The following screen will be displayed.
There are currently 3 options for editing a program. NotePROGRAM SIZEis calculated automatically as a
multiple of the number of rows and columns.
Set the NUMBER OF ROWSto the number of zones you want to have in a program. This number is limited
by the size of the controller you have purchased.
Set theNUMBER OF COLto the number of zones you want to run in parallel within the program.
Set the HOURS and MINSfield to “001” if you want to set zone run times in hours and minutes.
c. Reprogram General
To reset either individual functions of your controller or the whole controller to factory default settings use the
REPROG GENERAL” option from the Option Menu.
SelectREPROG GENERALfrom the Options Menu.
In order to reset a function or complete a factory reset, the corresponding code must be entered in the
REENTERfield and theREPROGfield set to Yes”.
For example to reset Auto Starts, theREENTERfield must be set to 086”.
PROG OPTIONS ROW 001
1 PROGRAM SIZE 016
2 NUMBER OF ROWS 006
3. NUMBER OF COL 000
4. HOURS and MINS 000
5
REPROGRAM
DATA CODE REENTER REPROG
AUTO STARTS 086 000 NO
PUMPS DELAY 118 000 NO
ZONE NAMES 150 000 NO
ZONE CONFIG 182 000 NO
DOSE OPTIONS 214 000 NO
FACTORY RESE 246 000 NO