Read the following table before completing programming of your EntryProx unit; it describes
various programming commands and how to execute them. As with the previously described
commands, you must first press 99 # (Master Code) * to enter programming mode, enter the
desired command sequence, and then press * to exit programming mode. “Ref” number is for
reference only, not to provide an ordered sequence of commands.
Ref Option Press Details
1 Enter program mode 99 # (Master
Code) *
Yellow LED blinks slowly
2 Program new master code into
user location 0
50 # 1 # 0000 #
master code *
master code *
Example: 4321 master code
(50 # 1 # 0000 # 4321 * 4321 *)
3 Set main relay time 11 # tt # 0 # ** tt = 1 - 99 seconds
4 Set AUX relay output 15 # output mode
# 0 # **
Output Modes:
0 = disabled,
1 = shunt,
2 = forced door,
3 = propped door
5 Delete users User Location #
**
Example: To delete user 100, press:
100#**
6 Download a transaction Log 70 # 0 # 0 # ** Obsolete. No longer supported.
7 Set/clear standard option 30 # option # s/c
# **
See the following Option
numbers and descriptions.
†† If Option 30# 14# is enabled, this sets the time that a card must be removed from the RF field before it
can be re-read. If option 30#14# is disabled, this sets the time between successive readouts, used in either
standalone or Wiegand mode.
Option Number/Description
0: Audio keypress feature
1: Visual keypress feature
2: Auto entry enable
3: Stand-alone/Wiegand operation
4: Facility code access (26-bit cards only)
Note: This disables the “toggle” card function.
5: Forced door audio alert
6: Propped door audio alert
7: Internal Request to Exit switch
8: US/EU Daylight Savings rollover dates
9: Wiegand red LED enable
10: Wiegand red LED active state
11: Wiegand green LED enable
12: Wiegand green LED active
13: Automatic Daylight Savings Time change
14: Prox card antipassback select
18: Invalid PIN lockout select
19: Invalid PIN lockout action
Set/Clear
0 = OFF/1 = ON
0 = OFF/1 = ON
0 = OFF/1 = ON (Recommend OFF)
0 = standalone/1=Wiegand
0 = OFF/1 = ON
0 = OFF/ 1 = ON
0 = OFF/1 = ON
0 = OFF/1 = ON
0 Y US/1 = European
0 = OFF/1 = ON
0 = LOW/1 = HIGH
0 = OFF/ 1 = ON
0 = LOW/1 = HIGH
0 = OFF/ 1 = ON
0 = OFF / 1= ON (prevents multiple card
reads in Wiegand mode)
0 = OFF / 1= ON
0 = TIMED LOCKOUT / 1 = Forced Door
Output
8 Download programmed user list 25 # 0 # 0# ** Obsolete. No longer supported.
9 Download programmed user list
(starting at a certain user)
25 # 0 # start
user # **
Obsolete. No longer supported.