Page 36 of 38 September 2016
EntryProx User Manual, 4045-905, Rev. C.4
11 LED/Sounder Status Indications
LED or Sounder Visual/Audible Condition Description
Yellow LED
Slow blink Unit is in Program mode
Rapid blink Verify mode is active (checking that the
last
two values in sequence match)
Steady Program error; to clear, press *
Very rapid blink Memory (EEPROM) erase is in progress
commands 40/46, 58 loop-back)
Bi-Color LED
Steady red Strike is locked
Steady green Strike is energized (timed or latched)
Slow blinking green Obsolete. No longer supported.
Solid green with red flicker Strike toggle is unlocked and used
lockout active
Red/green alternating Awaiting second form of ID during “Card
AND Code” access attempt
Red blink User lockout is active and strike locked;
red LED drops out for 100 ms every
second; normal users cannot change the
state of the relay. This also indicates
Invalid Pin Lockout.
Sounder
Short beep (100 ms) every 2 seconds Propped door is active
Sounder 1/2 second on, 1/2 second off Forced door is active
3 rapid beeps after code is entered or
card is presented
Code or Card is not found
3 slow beeps (250 ms), then a single
beep
Self-test is complete
1 single beep Valid card access