September 2016 Page 35 of 38
EntryProx User Manual, 4045-905, Rev. C.4
Ref Option Press Details
22 Program user:
Code OR Card
52 # user-type #
user location #
code* repeat
code *
<present card>
23 Program a group of consecutive
users by presenting cards
53 # user type #
start location # **
<present card>
<present card>
<present card>
…
Programs card-only users. Stops at user
location 2000, or press any key to abort.
Erases existing programming. If an existing
card is presented, an error will occur – press
* to resume
24 Perform batch entry of users:
Card only (26-bit cards ONLY)
56 # total count
# starting user
location #
starting card ID *
starting
card ID *
The card ID appears on the card; (Facility
Code must be entered first; see 32 # 2 #
command)
25 Block Delete Users 58 # start user #
start user #
number of users *
number of users *
Yellow LED blinks rapidly; allow several
seconds for large blocks of users. Cannot
delete: master user, more than 2000 users,
or user location greater than 2000.
26 Quick Enroll Card User Location # *
* <present card>
27 Download Transaction Log via
IR port
70 # 0 # 0 # ** Obsolete. No longer supported.
28 Set transaction log mask
(set/clear event logging)
73 # event # set/
clear # **
Prevent specified transactions from being
logged.
Set =0 (prevent)
Clear = 1 (restore)
See the following Code - Transaction Event
list.
Code – Transaction Event
01 – Access Denied
02 – Program Denied
04 – Request to Exit
05 – Door Ajar
06 – Door Closed
07 – Forced Door
10 – Invalid PIN Lockout
12 – Facility Code Access
16 – Obsolete. No longer supported.
17 – Access
20 – Toggle ON
21 – Toggle OFF
24 – Lockout ON
25 – Lockout OFF
27 – Mismatch
29 – Program Mode started
30 – Log erased
29 Reset transaction Log 76 # 00000 #
00000 # **
30 To exit Program mode * (after final
command)
Yellow LED stops flashing