EasyManua.ls Logo

HID ENTRYPROX - Page 35

HID ENTRYPROX
38 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
September 2016 Page 35 of 38
EntryProx User Manual, 4045-905, Rev. C.4
Ref Option Press Details
22 Program user:
Code OR Card
52 # user-type #
user location #
code* repeat
code *
<present card>
23 Program a group of consecutive
users by presenting cards
53 # user type #
start location # **
<present card>
<present card>
<present card>
Programs card-only users. Stops at user
location 2000, or press any key to abort.
Erases existing programming. If an existing
card is presented, an error will occur press
* to resume
24 Perform batch entry of users:
Card only (26-bit cards ONLY)
56 # total count
# starting user
location #
starting card ID *
starting
card ID *
The card ID appears on the card; (Facility
Code must be entered first; see 32 # 2 #
command)
25 Block Delete Users 58 # start user #
start user #
number of users *
number of users *
Yellow LED blinks rapidly; allow several
seconds for large blocks of users. Cannot
delete: master user, more than 2000 users,
or user location greater than 2000.
26 Quick Enroll Card User Location # *
* <present card>
27 Download Transaction Log via
IR port
70 # 0 # 0 # ** Obsolete. No longer supported.
28 Set transaction log mask
(set/clear event logging)
73 # event # set/
clear # **
Prevent specified transactions from being
logged.
Set =0 (prevent)
Clear = 1 (restore)
See the following Code - Transaction Event
list.
Code Transaction Event
01 Access Denied
02 Program Denied
04 Request to Exit
05 Door Ajar
06 Door Closed
07 Forced Door
10 Invalid PIN Lockout
12 Facility Code Access
16 – Obsolete. No longer supported.
17 Access
20 Toggle ON
21 Toggle OFF
24 Lockout ON
25 Lockout OFF
27 Mismatch
29 – Program Mode started
30 Log erased
29 Reset transaction Log 76 # 00000 #
00000 # **
30 To exit Program mode * (after final
command)
Yellow LED stops flashing

Table of Contents