Page 34 of 38 September 2016
EntryProx User Manual, 4045-905, Rev. C.4
Ref Option Press Details
10 Change Wiegand &
Miscellaneous parameters
32 # parameter #
value # **
Parameter/Value
0, Wiegand pulse width, default=8, 160µs,
(1=20µs), range= 1- 255
1, Wiegand interpulse spacing, default=32,
640µs, (1=20µs), range=1-255
2, Facility Code/0-225
(default = 1) (26-bit cards only) verify!
3, Process card timer 2 240 in ¼ second
increments, defaults to 4 1 second††
4, Invalid PIN lockout threshold 1 50
attempts (defaults to 5)
5, Invalid PIN lockout duration 1 255 in 5
second increments (defaults to 60 - 5
minutes)
11 Set system time 41 # hhmm # 0 #
**
hhmm = hour/minute,
24-hr format
12 Set system date 42 # mmddyy #
dow # **
mmddyy = month, day, year;
dow = day of week, where 1 = Sunday
13 Set door number 43 # nnnn # 0 #
**
nnnn = door number (for downloaded
reports)
14 Set propped door time (this sets
delay time for both the Aux
Relay and local sounder)
44 # ttt # 0 # ** ttt = propped door time, to nearest 10's
seconds, entered as 10 -990; default = 30
seconds
15 Set forced door time (this sets
active time for both the Aux
Relay and local
sounder)
45 # ttt # 0 # ** ttt = forced door time, to nearest 10's
seconds, entered as 10 - 990; default = 10
seconds
16 Delete memory except user list
and restore system defaults
(also see command 46)
40 # 00000 #
00000 # **
17 Delete all memory and reset
system defaults
46 # 00000 #
00000 # **
18 Program user:
Code ONLY
Note: You can program the four
types of users shown to the
right
50 # user-type #
user location #
code * repeat
code *
User Types:
0 - Toggle/latch strike
1 - Normal Access
2 - Log Download
3 - Lockout
19 Program user:
Code AND Card
50 # user-type #
user location #
code * repeat
code *
<present card>
20 Program user:
Card ONLY
50 # user-type #
user location # *
*
<present card>
20A Program new master code into
user location 0
50 # 1 # 0000 #
master code *
master code *
21 Program card user manually:
Card Only (26-bit cards ONLY)
51 # user-type #
user location #
card ID * card ID
*
The card ID appears on the card (Facility
Code must be entered first; see 32 # 2 #
command)

Table of Contents