EasyManuals Logo

HIKVISION Hik IP Receiver Pro User Manual

HIKVISION Hik IP Receiver Pro
67 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #44 background imageLoading...
Page #44 background image
Check the parameter to enable spare ARC.
Spare ARC IP Address
Enter the IP Address of the spare ARC.
Spare ARC Port
Enter the spare ARC port number.
Line Card Number
Line number, which ranges from 1 to 999.
Connecng Mode
There are two link modes: dedicated and disconnuous.
Test Signal Interval
It ranges from 60 to 300. Valid when the link mode is disconnuous.
Test Signal ID
Up to 12 characters are allowed. It is GATEWAY by default. Valid when the link mode is
disconnuous.
Test Signal Event Type
Up to 16 characters are allowed. It is SYS by default. Valid when the link mode is
disconnuous.
Test Signal Event ID
Up to 16 characters are allowed. It is *RP by default. Valid when the link mode is
disconnuous.
Enable Device Heartbeat
Check the parameter to enable device heartbeat. It is disabled by default.
Device Heartbeat Interval
It ranges from 10 to 86400 seconds. It is 30 seconds by default.
Note
Used for the device which does not support Periodic Test or whose Periodic Test has not
been enabled. If the Periodic Test of a device has been enabled, then the device heartbeat
interval will be the same as that of this device.
SBN
IP Address
Enter the IP address of the ARC which supports SBN protocol.
Port
The port used for the connecon with the ARC which supports SBN protocol. By default, it
is 1025.
Spare ARC
Hik IP Receiver Pro User Manual
39

Table of Contents