3.3 Drying system: what to do if. . .
The machine doesn’t dry well
1. The machine is switched off Switch on the machine.
2. The machine doesn’t switch on Refer to the proper section (see section
3.1 at page 9).
3. The recovery tank is full Empty the recovery tank following
the proper procedure.
4. The vacuum motor doesn’t switch
on
Refer to the proper section (see section
3.3 at page 14).
5. The machine is in ”ECO” mode Set up the machine as per standard
configuration.
6. The squeegee is lifted up from the
floor
Lower down the squeegee.
7. The squeegee rubber blades are
worn out or broken
Rotate or replace the squeegee rub-
ber blades.
8. The squeegee is not properly ad-
justed
Adjust the squeegee properly follow-
ing the proper procedure (see section 7.3.1
at page 51).
9. The squeegee vacuum chamber or
adapter is stuck or dirty
Clean the squeegee vacuum cham-
ber (see section 7.4.1 at page 52).
10. The vacuum hose is stuck or bro-
ken
Clean or replace the vacuum hose.
11. The vacuum hose is not properly
fitted in
Connect the vacuum hose properly.
12. The intake manifold is stuck or bro-
ken
Clean or replace the intake manifold
(see section 7.4.6 at page 53).
13. The intake manifold is not properly
connected
Connect the intake manifold prop-
erly.
14. The vacuum filter is dirty or stuck Disassemble and clean the vacuum
filter.
15. The vacuum cover is not well posi-
tioned or is missing
Position properly the vacuum cover.
16. The vacuum cover gasket doesn’t
adhere properly
Replace the vacuum cover gasket.
13