General Battery Parameters
Parameter Default Min ÷ Max Description
General - Battery
Battery Type
Gel60 Battery Type.
Pb60 - Gel60 - PPb - Pb80 - Gel80 - Custom
General - Battery
Delay Time #sec
30 5 ÷ 300 Battery status refresh rate.
General - Battery
Reset Level #%
80 10 ÷ 100 The charge level necessary to reset the hormeter.
General - Battery
Brushes off Level #%
20 0 ÷ 100 Charge threshold beyond which the Brush Motor is inhibited.
General - Battery
Vacuum off Level #%
10 0 ÷ 100 Charge threshold beyond which the Vacuum Motor is inhib-
ited.
General - Battery
Traction off Level #%
0 0 ÷ 100 Charge threshold beyond which the Traction Motor is inhib-
ited.
General - Battery
Custom Level 5/5 #V
23.5 15.0 ÷ 40.0 Valid on Custom Battery Parameter: Battery Level 100%.
General - Battery
Custom Level 4/5 #V
23.0 15.0 ÷ 40.0 Valid on Custom Battery Parameter: Battery Level 80%.
General - Battery
Custom Level 3/5 #V
22.5 15.0 ÷ 40.0 Valid on Custom Battery Parameter: Battery Level 60%.
General - Battery
Custom Level 2/5 #V
22.0 15.0 ÷ 40.0 Valid on Custom Battery Parameter: Battery Level 40%.
General - Battery
Custom Level 1/5 #V
21.5 15.0 ÷ 40.0 Valid on Custom Battery Parameter: Battery Level 20%.
General - Battery
Custom Level 0/5 #V
21.0 15.0 ÷ 40.0 Valid on Custom Battery Parameter: Battery Level 0%.
General Hourmeter Parameters
Parameter Default Min ÷ Max Description
General - Hourmeter
Partial Hourmeter display
Tr Available hourmeters (0=Key; 1=Tr; 2=Br; 3=Vac).
General - Hourmeter
Reset Partial Hourmeter
No Reset of the single hourmeters (Key=Key; Tr=Traction;
Br=Brush; Vac=Vacuum).
General - Hourmeter
Reset Main Hourmeter
No (No; Key=Key; Tr=Traction; Br=Brush; Vac=Vacuum).
General Access Parameters
Parameter Default Min ÷ Max Description
General - Access Mode
Password 2 (Dealer)
3222 3000 ÷ 3999 Dealer Password.
General - Access Mode
Password 3 (Customer)
2234 2000 ÷ 2999 Customer Password.
General - Access Mode
Password 4 (User)
1000 1000 ÷ 1999 User Password.
General - Access Mode
Password 5 (PIN)
123 100 ÷ 999 PIN.
General - Access Mode
Password Enable: User
Yes No ÷ Yes User Password Enable; 0=OFF; 1=ON
General - Access Mode
Password Enable: PIN
Yes No ÷ Yes PIN Enable; 0=OFF; 1=ON