EasyManua.ls Logo

Hirschmann HiSecOS EAGLE20 - Page 224

Hirschmann HiSecOS EAGLE20
532 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Virtual Private Network > Connections
Virtual Private Network
224
RM GUI HiSecOS EAGLE20/30
Release
3.0
09/2015
IPSec Encryption Specifies the algorithm that the device uses for IPsec encryption.
Possible values:
any
The device accepts every algorithm when you specify it to be a
responder, and uses various pre-defined algorithms as the initiator.
des
The device uses the Data Encryption Standard (DES) block cipher for
encryption of message data with a 56-bit key.
des3
The device uses the Triple DES block cipher for encryption of message
data which applies the 56-bit key, from DES, 3 times to each block.
aes128
(default setting)
The device uses the Advanced Encryption Standard (AES) with a block
size of 128 bits, and a key length of 128 key bits.
aes192
The device uses the AES with a block size of 128 bits, and a key length
of 192 key bits.
aes256
The device uses the AES with a block size of 128 bits, and a key length
of 256 key bits.
aes128gcm64
The device uses the AES-Galois/Counter Mode (GCM) with a 64 bit
Integrity Check Value (ICV) and 128 key bits.
aes128gcm96
AES-GCM with a 96 bit ICV and 128 key bits.
aes128gcm128
AES-GCM with a 128 bit ICV and 128 key bits.
aes192gcm64
AES-GCM with a 64 bit ICV and 192 key bits.
aes192gcm96
AES-GCM with a 96 bit ICV and 192 key bits.
aes192gcm128
AES-GCM with a 128 bit ICV and 192 key bits.
aes256gcm64
AES-GCM with a 64 bit ICV and 256 key bits.
aes256gcm96
AES-GCM with a 96 bit ICV and 256 key bits.
aes256gcm128
AES-GCM with a 128 bit ICV and 256 key bits.
IPSec Lifetime [s] Specifies the lifetime, in seconds, of the IPsec security association between
two network devices to support secure communication. The devices
establish a security association after exchanging a set of pre-defined keys.
Possible values:
300..28800
(default setting:
3600
)
The default setting is 1 hour and the maximum setting is 8 hours.
Parameters Meaning

Table of Contents

Related product manuals