Diagnostics > Report > Global
Diagnostics
464
RM GUI HiSecOS EAGLE20/30
Release
3.0
09/2015
Buffered Logging
The device buffers logged events in 2 separate storage areas so that the
log entries for urgent events are kept.
This dialog allows you to specify the minimum severity for events that the
device buffers in the storage area with a higher priority.
CLI Logging
Parameters Meaning
Severity Specifies the minimum severity for the events. The device buffers log
entries for events with this severity and with more urgent severities in the
storage area with a higher priority.
Possible values:
emergency
alert
critical
error
warning
(default setting)
notice
informational
debug
Parameters Meaning
Operation If the function is enabled, the device logs all commands received via the
Command Line Interface (CLI).
Possible values:
"On"
"Off" (default setting)

Table of Contents