Introduction HS 200UTV-2/HS 250UTV-2
1-41
new if they are loose tighten them as follows:
Torque wheel bolts to 75 to 90 N.m
Cleaning air cleaner primary element
1. Remove the air cleaner cover and primary
element.
2. Clean the primary elements.
1 When dry dust adheres to the element
blow compressed air from the inside
turning the element. Pressure of
compressed air must be under 205kpa.
2 When carbon or oil adheres to the element
soak the element in detergent for 15
minutes then wash it several times in
water rinse with clean water and dry it
naturally after element is fully dried inspect
inside of the element with a light and
check if it is damaged or not.
3 Replace the primary element
Once yearly or after every sixth cleaning,
whichever comes first.
First air cleaner Air cleaner case
Air cleaner element Cover
IMPORTANT
The air cleaner uses a dry element never
apply oil.
Do not run the engine with filter element
removed.
Be sure to refit the cower with the arrow
(on the rear of cower ) upright. if the cover
is improperly fitted the evacuator valve will
not function and dust will adhere to the
element.
Evacuator Valve
Open the air cleaner cover once a week under
ordinary conditions or daily when used in a
dusty place-to get rid of large particles of dust
and dirt.
Check fuel line and fuel filter.
CAUTION
To avoid personal injury:
Be sure to stop the engine and remove