117
Message Description
The horizontal or vertical frequency of the input 
VLJQDOLVQRWZLWKLQWKHVSHFL¿HGUDQJH
Please conrm the specs for your projector or the signal 
source specs.
An improper signal is input. 
Please conrm the specs for your projector or the signal 
source specs.
The internal temperature is rising.
Please turn the power off, and allow the projector to cool 
down at least 20 minutes. After having conrmed the 
following items, please turn the power ON again. 
 • Is there blockage of the air passage aperture? 
 • Is the air lter dirty? 
 • Does the peripheral temperature exceed 45°C? 
 •  If you use CP-X8150, CP-WX8240, CP-SX8350 or 
CP-WU8440, does the peripheral temperature exceed 
40°C?
 • Is the setting for ALTITUDE appropriate? 
For details of ALTITUDE, refer to ALTITUDE of 
SERVICE in the OPTION menu (
67). If the projector is 
used with a wrong setting, it may cause damage to the 
projector itself or the parts inside.
$QRWHRISUHFDXWLRQZKHQFOHDQLQJWKHDLU¿OWHU
Please immediately turn the power off, and clean or 
change the air lter referring to the Cleaning and 
UHSODFLQJWKHDLU¿OWHU section of this manual. After you 
have cleaned or changed the air lter, please be sure to 
reset the lter timer (
65, 113).
The button operation is not available.
Check the button you are going to use (
6). Even when 
a usable button is pressed, all button operations are not 
available under the following conditions.
-  While the lens is moving, button operation from the 
control panel or the remote control might be ignored.
-  Pressing the one of buttons to call a signal input might 
be ignored, when all the input ports belonging to the 
category the button's name shows are set to the "SKIP" 
by the item SOURCE SKIP of the OPTION menu.
Troubleshooting