23
A C 2 4 0 V 3 5 ° C
7 F I L T E R E R R O
1 P R E V I O U S
 To display error history
Press the ▲ button to display previous error 
log. If a warning has been displayed, the 
rst previous error log is the present error 
currently occurring. The Status Monitor 
displays the log number, occurred error, the 
supplied voltage and peripheral temperature 
at that time. Press the ► button to display 
the usage time when each error occurred. 
Use the ▲/▼ buttons to switch the log. 
The display switches with the ◄/► 
buttons at each log. Up to 10 error 
logs including the present one can be 
displayed.
Status Monitor  <Only for CP-X8160, CP-WX8250 and CP-WU8450> 
• The Status Monitor and its backlight returns to the rst state before 
the FUNCTION or ENTER button was pressed when any button except cursor 
buttons is pressed, or after about 30 seconds without button operation.
• If no error or less than 10 errors have occurred, "NO DATA" is displayed in 
spite of occurred error in the error log. 
NOTE
Displaying the log (continued)
• The Status Monitor and its backlight returns to the rst state before 
the FUNCTION or ENTER button was pressed when any button except cursor 
buttons is pressed, or after about 30 seconds without button operation.
• The projector usage time is the total lamp time from the projector is 
manufactured. It is not reset by using LAMP TIME in the OPTION menu (
65).
• If the ▲/▼ buttons are pressed while the usage time is displayed, the usage 
time switches to the past one when an error occurred.
NOTE
Error log 1
Error log 10
First display
Usage time 
(error log 1)
Usage time 
(current)
Usage time 
(error log 10)
Error log (example)
Log number
Error