Critical High Forward Power 
 
Power Amplifier Drawer forward output power is greater than 
1300Watts. 
Default system action: Shutdown. 
 
Critical High Reflected Power 
 
Drawer reflected output power is greater than 184Watts. 
Default system action: Shutdown. 
 
Critical High Input Air Temperature 
 
Ambient air temperature used in the reflow of the equipment is 
greater than 48°C (118,4ºF). 
Default system action: Shutdown. 
 
High Input Air Temperature 
 
Ambient air temperature used in the reflow of the equipment is 
greater than 35°C (95ºF). 
Default system action: Notification. 
 
 
RF Input Level is less than -8dBm 
Default system action: Notification. 
 
 
RF Input Level is greater than 10dBm 
Default system action: Notification. 
 
 
Current at the indicated PA is greater than 10A. 
Default system action: Notification. 
 
PA__ Critical High Current 
 
Current at the indicated PA is greater than 10A. 
Default system action: Shutdown. 
 
 
Current at the indicated PA is less than 0.2A. 
Default system action: Shutdown. 
 
 
Current in the indicated PA is 2.5A is higher or lower than the 
others. 
Default system action: Notification. 
 
 
Temperature at the indicated PA is greater than 75ºC (167ºF). 
Default system action: Notification. 
 
PA__ Critical High Temperature 
 
Temperature at the indicated PA is greater than 80ºC (176ºF). 
Default system action: Shutdown. 
 
 
Indicated PA Gain is Less than 49dB. 
Default system action: Notification