Hitachi Advanced Server HA820 G2 User Guide 112
6.
Remove all riser cages
.
7.
Connect the power cable to the drive backplane power connector on the system board.
8.
If connecting the data cable to the system board or a controller, connect the data cable.
9.
Prepare the drive cage for installation by lifting the latches on the drive cage.
10.
Install the drive cage:
CAUTION:
Do not drop the drive cage on the system board. Dropping the drive cage on the system
board might damage the system or components. Remove all drives and use two hands when
installing or removing the drive cage.
a.
Locate the alignment pins on the rear of the drive cage.
b.
Align the pin on the rear left of the drive cage to the server and then insert the pin.
c.
Gently lower the opposite side of the drive cage.