Hitachi Advanced Server HA820 G2 User Guide 46
Procedure
1.
Power down the server.
2.
Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
3.
Do one of the following:
Extend the server from the rack.
Remove the server from the rack.
4.
Remove the access panel.
5.
Remove the riser cage.
6.
Remove the blank.
Removing the hard drive blank
CAUTION:
To prevent improper cooling and thermal damage, do not operate the server unless all bays
are populated with either a component or a blank.
Figure 1 Removing an SFF drive blank