Hitachi Advanced Server HA820 G2 User Guide 113
d.
Pull the plunger pin on the rear right of the drive cage and then lower the drive cage until
the plunger pin engages.
11.
Install drives or drive blanks.
12.
Push down on the latches to lower the drive cage into place.
13.
Connect the power and data cables to the drive backplane.
Installing a rear 2 SFF SAS/SATA drive cage in the primary or secondary riser