13
Code
Name
Default Setting
-FE(CE) -FU(UL)
Run-time
Setting
Run-time Data Edit
(Enabled at b031)
Description
d001
d002
d003
d004
d005
d006
d007
d012
d013
d014
d016
d017
d080
d090
F001
F002
F202
F302
F003
F203
F303
F004
A---
b---
C---
H---
P---
U---
Output frequency monitor
Output current monitor
Motor rotational direction monitor
Process variable (PV), PID feedback monitor
Intelligent input terminal status
Intelligent output terminal status
Scaled output frequency monitor
Torque monitor
Output voltage monitor
Power monitor
Cumulative RUN time monitor
Cumulative power-on time monitor
Trip count monitor
Trip monitor 1
-
6
Warning monitor
Output frequency setting
Acceleration time (1) setting
Acceleration time (1) setting for second motor
Acceleration time (1) setting for third motor
Deceleration time (1) setting
Deceleration time (1) setting for second motor
Deceleration time (1) setting for third motor
Motor rotational direction setting
A Group: Standard functions
b Group: Fine tuning functions
C Group: Intelligent terminal functions
H Group: Motor constants functions
P Group: Expansion card functions
U Group: User-selectable menu functions
FUNCTION LIST
●MONITORING FUNCTIONS and MAIN P ROFILE PARAMETERS
●A GROUP: STANDARD FUNCTIONS
Expanded Function
Monitor Mode
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
0.00Hz
30.00s
30.00s
30.00s
30.00s
30.00s
30.00s
00
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
0.00Hz
30.00s
30.00s
30.00s
30.00s
30.00s
30.00s
00
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
◯
◯
◯
◯
◯
◯
◯
×
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
◯
◯
◯
◯
◯
◯
◯
×
Setting Mode
(Example) FW, 7, 2, 1 : ON
8, 6, 5, 4, 3 : OFF
(Example) 12, 11 : ON
AL, 15, 14, 13 :OFF
Multispeed and Jogging Frequency Setting
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
Code
Name
Default Setting
-FE(CE) -FU(UL)
Run-time
Setting
Run-time Data Edit
(Enabled at b031)
Description
A002
A003
A203
A303
A004
A204
A304
A011
A012
A013
A014
A015
A016
A020
A220
A320
A038
Run command source setting
Base frequency setting
Base frequency setting for second motor
Base frequency setting for third motor
Maximum frequency setting
Maximum frequency setting for second motor
Maximum frequency setting for third motor
O-L input active range start frequency
O-L input active range end frequency
O-L input active range start voltage
O-L input active range end voltage
O-L input start frequency enable
External frequency filter time constant
Multispeed frequency setting (0)
Multispeed frequency setting (0) for second motor
Multispeed frequency setting (0) for third motor
Multispeed frequency setting (1-15)
Jog frequency setting
01(Terminals) / 02(Operator) / 03(RS-485) / 04(Expansion card 1) / 05(Expansion card 2)
30.Hz-Maximum frequency
30.Hz-Maximum frequency for second motor
30.Hz-Maximum frequency for third motor
30.
-
400.Hz
30.
-
400.Hz
30.
-
400.Hz
0.00
-
400.0Hz
0.00
-
400.0Hz
0.
-
100.%
0.
-
100.%
00(External frequency output zero reference)/ 01(0Hz)
1.
-
30.(Sampling time=2msec.)
0.0, Starting frequency to maximum frequency
0.0, Starting frequency to maximum frequency for second motor
0.0, Starting frequency to maximum frequency for third motor
0.0, Starting frequency to maximum frequency
0.0, Starting frequency to 9.99Hz
Basic Setting
01
50.
50.
50.
50.
50.
50.
0.00
0.00
0.
100.
01
8.
0.00
0.00
0.00
0.00
1.00
×
×
×
×
×
×
×
×
×
×
×
×
×
◯
◯
◯
◯
◯
×
×
×
×
×
×
×
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
Analog Input Setting
01
01
60.
60.
60.
60.
60.
60.
0.00
0.00
0.
100.
01
8.
0.00
0.00
0.00
0.00
1.00
01
× ×Frequency source setting
A001
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
00(Potentiometer) / 01(Terminals) / 02(Operator) / 03(RS485)/
04(Expansion card 1) / 05(Expansion card 2)
00(Binary: up to 16-stage speed at 4 terminals)
/ 01(Bit: up to 8-stage speed at 7 terminals)
00
00
×
×
A019 Multispeed operation selection
00(Free-run stop/disable during RUN)/ 01(Deceleration to
stop/disable during RUN)/ 02(DC braking to stop/disable dur-
ing RUN)/ 03(Free-run stop/enable during RUN)/ 04(Decelera-
tion to stop/enable during RUN)/ 05(DC braking to stop/enable
during RUN)
A039
Jog stop mode
×
0000
◯
A021
I
A035
A005
A006
AT selection
00(Selection between O and OI at AT)
/ 01(Selection between O and O2 at AT)
00
03
00
03
×
×
×
×
O2 selection
00(Independent)/ 01(Only positive)
/ 02(Both positive and negative)/ 03(Disable)
= Allowed
= Not permitted
◯
×
[ ]
◯
= Allowed
= Not permitted
◯
×
[ ]
0.00
-
99.99/100.0
-
400.0Hz
0.0
-
999.9A
F(Forward) / o(Stop) / r(Reverse)
0.00
-
99.99/100.0
-
999.9/1000.
-
9999./1000
-
9999/「100
-
「999(10,000
-
99,900)
0.00
-
99.99/100.0
-
999.9/1000.
-
9999./1000
-
3996(10,000
-
39,960)
-
300.
-
+300.
0.0
-
600.0V
0.0
-
999.9kW
0.
-
9999./1000
-
9999/「100
-
「999(10,000
-
99,900)hr
0.
-
9999./1000
-
9999/「100
-
「999(10,000
-
99,900)hr
0.
-
9999./1000
-
6553(10,000
-
65,530)
Displays trip event information
Warning code
0.0, Starting frequency to maximum frequency (maximum frequency for second and third motor)
0.01
-
99.99/100.0
-
999.9/1000.
-
3600. sec.
0.01
-
99.99/100.0
-
999.9/1000.
-
3600. sec.
0.01
-
99.99/100.0
-
999.9/1000.
-
3600. sec.
0.01
-
99.99/100.0
-
999.9/1000.
-
3600. sec.
0.01
-
99.99/100.0
-
999.9/1000.
-
3600. sec.
0.01
-
99.99/100.0
-
999.9/1000.
-
3600. sec.
00(Forward)/01(Reverse)
%
FW
5487 2361
ON
OFF
AL
1213 1115 14
ON
OFF
-
d081
d086