17
Note:[]75kW and over
[0.
-
180.%]
[0.
-
180.%]
[0.
-
180.%]
[0.
-
180.%]
[
0.2
-
160
(kW)
]
[
0.2
-
160
(kW)]
●H GROUP: MOTOR CONSTANTS FUNCTIONS
C031
C032
C033
C034
C035
C036
C040
C041
C042
C043
C044
C045
C046
C055
C056
C057
C058
C061
C062
C063
C070
C071
C072
C073
C074
C075
C078
C081
C082
C083
C085
C086
C087
C088
C091
C101
C102
C103
C111
C121
C122
C123
Terminal (11) active state
Terminal (12) active state
Terminal (13) active state
Terminal (14) active state
Terminal (15) active state
Alarm relay terminal active state
Overload signal output mode
Overload level setting
Arrival frequency setting for acceleration
Arrival frequency setting for deceleration
PID deviation level setting
Arrival frequency setting for acceleration(2)
Arrival frequency setting for deceleration(2)
Over-torque(Forward-driving) level setting
Over-torque(Reverse-regenerating) level setting
Over-torque(Reverse-driving) level setting
Over-torque(Forward-regenerating) level setting
Electronic thermal warning level setting
Alarm code input
Zero speed detection level
Data command method
Communication speed selection
Node allocation
Communication data length selection
Communication parity selection
Communication stop bit selection
Communication wait time
O input span calibration
OI input span calibration
O2 input span calibration
Thermistor input tuning
AM terminal offset tuning
AMI terminal meter tuning
AMI terminal offset tuning
Debug mode enable
UP/DOWN memory mode selection
Reset mode selection
Restart frequency after reset
Overload level setting(2)
O input zero calibration
OI input zero calibration
O2 input zero calibration
Free-setting V/f pattern
Serial Communication
Analog Meter SettingOthers
00
00
00
00
00
01
01
Rated current
0.00
0.00
3.0
0.00
0.00
100.
100.
100.
100.
80.
00
0.00
02
04
1.
7
00
1
0.
Factory set
Factory set
Factory set
105.0
0.0
80.
4.0
00
00
00
00
Rated current
Factory set
Factory set
Factory set
00
00
00
00
00
01
01
Rated current
0.00
0.00
3.0
0.00
0.00
100.
100.
100.
100.
80.
00
0.00
02
04
1.
7
00
1
0.
Factory set
Factory set
Factory set
105.0
0.0
80.
4.0
00
00
00
00
Rated current
Factory set
Factory set
Factory set
H001
H002
H202
H003
H203
H004
H204
H005
H205
H006
H206
H306
Auto-tuning setting
Motor data selection for first motor
Motor data selection for second motor
Motor capacity
Motor capacity for second motor
Motor poles setting
Motor poles setting for second motor
Motor speed constant
Motor speed constant for second motor
Motor stabilization constant
Motor stabilization constant
for second motor
Motor stabilization constant for third motor
00(NOR:Disable) / 01(NOR:No rotation) / 02(AUT:Rotation)
00(Hitachi standard motor) / 01(Auto-data) / 02(Adaptive-data)
00(Hitachi standard motor) / 01(Auto-data) / 02(Adaptive-data)
0.20
-
75.0(kW)
0.20
-
75.0(kW)
2/4/6/8
2/4/6/8
0.001
-
9.999/10.00
-
65.53
0.001
-
9.999/10.00
-
65.53
0.
-
255.
0.
-
255.
0.
-
255.
00
00
00
Factory set
Factory set
4
4
1.590
1.590
100.
100.
100.
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
◯
◯
◯
◯
◯
◯
◯
×
×
×
×
×
◯
◯
◯
Motor Constants and Gain Setting
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
×
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
×
×
×
×
×
×
×
◯
◯
◯
◯
◯
×
×
×
×
×
×
×
◯
◯
◯
◯
◯
Code
Name
Default Setting
-FE(CE) -FU(UL)
-FE(CE) -FU(UL)
Run-time
Setting
Run-time Data Edit
(Enabled at b031)
Description
Code
Name
Default Setting
Run-time
Setting
Run-time Data Edit
(Enabled at b031)
Description
00(Cancel trip state when reset signal turns ON) / 01(Cancel
trip state when reset signal turns OFF) / 02(Cancel trip state
when reset signal turns ON(Enable during trip state))
0.000
-
9.999/10.00
-
65.53
0.000
-
9.999/10.00
-
65.53
0.000
-
9.999/10.00
-
65.53
0.000
-
9.999/10.00
-
65.53
0.00
-
9.99/100.00
-
655.3
0.00
-
9.99/100.00
-
655.3
Motor constant R1 setting for first motor
Motor constant R1 setting for second motor
Motor constant R2 setting for first motor
Motor constant R2 setting for second motor
Motor constant L setting for first motor
Motor constant L setting for second motor
H020
H220
H021
H221
H022
H222
According
to capacity
According
to capacity
According
to capacity
According
to capacity
According
to capacity
According
to capacity
00
00
00
Factory set
Factory set
4
4
1.590
1.590
100.
100.
100.
According
to capacity
According
to capacity
According
to capacity
According
to capacity
According
to capacity
According
to capacity
×
×
×
×
×
×
×
×
×
×
×
×
= Allowed
= Not permitted
◯
×
[ ]
= Allowed
= Not permitted
◯
×
[ ]
◯
◯
◯
00(NO) / 01(NC)
00(NO) / 01(NC)
00(NO) / 01(NC)
00(NO) / 01(NC)
00(NO) / 01(NC)
00(NO) / 01(NC)
00(During accel./decel) / 01(At constant speed)
0.00
×rated current-2.00×rated current
0.00
-
99.99/ 100.0
-
400.0Hz
0.00
-
99.99/ 100.0
-
400.0Hz
0.0
-
100%
0.00
-
99.99/ 100.0
-
400.0Hz
0.00
-
99.99/ 100.0
-
400.0Hz
0.
-
200.%
0.
-
200.%
0.
-
200.%
0.
-
200.%
0.
-
100.%
00(Disabled) / 01(3-bit) / 02(4-bit)
0.00-99.99/100.0Hz
02(Operator) / 03(RS-485) / 04 (Expansion card 1) / 05(Expansion card 2)
02(Test) / 03(2400bps) / 04(4800bps) / 05(9600bps) / 06(19200bps)
1.
-
32.
7(7-bit) / 8(8-bit)
00(No parity) / 01(Even) / 02(Odd)
1(1-bit) / 2(2-bit)
0.
-
1000.msec.
0
-
6553(65,530)
0
-
6553(65,530)
0
-
6553(65,530)
0.0
-
1000.
0.0
-
10.0V
0.
-
255.%
0.
-
20.0mA
00(No display) / 01(Display)
00(Clear previous frequency) / 01(Keep previous frequency)
00(Restart at 0Hz) / 01(Resume operation after frequency matching)
0.00
×rated current-2.00×rated current
0.
-
9999./ 1000
-
6553(10,000
-
65,530)
0.
-
9999./ 1000
-
6553(10,000
-
65,530)
0.
-
9999./ 1000
-
6553(10,000
-
65,530)