16
●C GROUP: INTELLIGENT TERMINAL FUNCTIONS
b100
b101
b102
b103
b104
b105
b106
b107
b108
b109
b110
b111
b112
b113
b120
b121
b122
b123
b124
b125
b126
Free-setting V/f frequency (1)
Free-setting V/f voltage (1)
Free-setting V/f frequency (2)
Free-setting V/f voltage (2)
Free-setting V/f frequency (3)
Free-setting V/f voltage (3)
Free-setting V/f frequency (4)
Free-setting V/f voltage (4)
Free-setting V/f frequency (5)
Free-setting V/f voltage (5)
Free-setting V/f frequency (6)
Free-setting V/f voltage (6)
Free-setting V/f frequency (7)
Free-setting V/f voltage (7)
Brake control enable
Brake wait time for release
Brake wait time for acceleration
Brake wait time for stopping
Brake wait time for confirmation
Brake release frequency setting
Brake release current setting
0.0
-
Free-setting V/f frequency (2)
0.0
-
800.0V
0.0
-
Free-setting V/f frequency (3)
0.0
-
800.0V
0.0
-
Free-setting V/f frequency (4)
0.0
-
800.0V
0.0
-
Free-setting V/f frequency (5)
0.0
-
800.0V
0.0
-
Free-setting V/f frequency (6)
0.0
-
800.0V
0.0
-
Free-setting V/f frequency (7)
0.0
-
800.0V
0.
-
400.Hz
0.0
-
800.0V
00(Disable) / 01(Enable)
0.00
-
5.00sec.
0.00
-
5.00sec.
0.00
-
5.00sec.
0.00
-
5.00sec.
0.00
-
99.99/100.0
-
400.0Hz
0.00
×rated current to 2.00×rated current
Free-setting V/f pattern
0.
0.0
0.
0.0
0.
0.0
0.
0.0
0.
0.0
0.
0.0
0.
0.0
00
0.00
0.00
0.00
0.00
0.00
Rated current
C001
C002
C003
C004
C005
C006
C007
C008
C011
C012
C013
C014
C015
C016
C017
C018
C019
C022
C027
C028
C029
Terminal (1) function
Terminal (2) function
Terminal (3) function
Terminal (4) function
Terminal (5) function
Terminal (6) function
Terminal (7) function
Terminal (8) function
Terminal (1) active state
Terminal (2) active state
Terminal (3) active state
Terminal (4) active state
Terminal (5) active state
Terminal (6) active state
Terminal (7) active state
Terminal (8) active state
Terminal FW active state
Terminal (12) function
FM signal selection
AM signal selection
AMI signal selection
00(NO) / 01(NC)
00(NO) / 01(NC)
00(NO) / 01(NC)
00(NO) / 01(NC)
00(NO) / 01(NC)
00(NO) / 01(NC)
00(NO) / 01(NC)
00(NO) / 01(NC)
00(NO) / 01(NC)
18
(RS)
16
(AT)
06
(JG)
11
(FRS)
09
(2CH)
03
(CF2)
(CF1)
01
(RV)
00
00
00
00
00
00
00
00
00
00
00
00
0.
0.0
0.
0.0
0.
0.0
0.
0.0
0.
0.0
0.
0.0
0.
0.0
00
0.00
0.00
0.00
0.00
0.00
Rated current
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
Intelligent Input Terminal Setting
Intelligent Input Terminal State Setting
Intelligent Output Terminal Setting
×
×
×
×
×
×
×
×
×
×
×
×
×
×
◯
◯
◯
◯
◯
◯
◯
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
◯
Code
Name
Default Setting
-FE(CE) -FU(UL)
Run-time
Setting
Run-time Data Edit
(Enabled at b031)
Description
Code
Name
Default Setting
-FE(CE) -FU(UL)
Run-time
Setting
Run-time Data Edit
(Enabled at b031)
Description
00(RUN:Run signal)/ 01(FA1:Frequency arrival signal (at the set frequency))/
02(FA2:Frequency arrival signal (at or above the set frequency))/ 03(OL:Overload
advance notice signal)/ 04(OD:Output deviation for PID control)/ 05(AL:Alarm sign-
al)/ 06(FA3:Frequency arrival signal (only at the set frequency))/ 07(OTQ:Over-
torque) / 08(IP:Instantaneous power failure signal)/ 09(UV:Under-voltage signal)/
10(TRQ:In torque limit)/ 11(RNT:RUN time over)/ 12(ONT:Power-on time over)/
13(THM:Thermal alarm)/ 19(BRK:Brake release)/ 20(BER:Brake error)/ 21(ZS:Zero
speed)
22(DSE:Speed deviation excessive) / 23(POK:Positioning completion)
24(FA4:Frequency arrival signal (at or above the set frequency)(2))/ 25(FA5:Fre-
quency arrival signal (only at the set frequency)(2))/ 26(OL2:Overload advance
notice signal(2))
(Terminal 11
-
13 or 11
-
14 are automatically configured as AC0
-
AC2 or AC0
-
AC3
per alarm code output selection)
00(Output frequency) / 01(Output current) / 02(Output torque) /
03(Digital output frequency-only at C027) / 04(Output voltage)
/ 05(Power) / 06(Thermal load ratio) / 07(LAD frequency)
C026
C021
Terminal (11) function
03
(OL)
05
(AL)
01
(FA1)
02
18
(RS)
16
(AT)
06
(JG)
11
(FRS)
09
(2CH)
13
(USP)
(CF1)
01
(RV)
00
00
00
00
00
01
00
00
00
00
00
00
03
(OL)
05
(AL)
01
(FA1)
02
×
×
×
◯
◯
◯
◯
C025
Terminal (15) function
C024
Terminal (14) function
00
(RUN)
00
(RUN)
07
(OTQ)
07
(OTQ)
×
◯
×
×
◯
◯
08
(IP)
08
(IP)
×
01(RV:Reverse) / 02(CF1:Multipeed(1)) / 03(CF2:Multispeed(2)) / 04(CF3:Multi-
speed(3)) / 05(CF4:Multispeed(4)) / 06(JG:Jogging) / 07(DB:External DC braking) /
08(SET:Second motor constants setting) / 09(2CH:Second accel./decel.) /
11(FRS:Free-run stop) / 12(EXT:External trip) / 13(USP:Unattended start protection) /
14(CS:Change to/from commercial power supply) / 15(SFT:Software lock) /
16(AT:Analog input selection) / 17(SET3:Third motor constants setting) /
18(RS:Reset) / 20(STA:3-wire start) / 21(STP:3-wire stop) / 22(F/R:3-wire fwd./
rev.) / 23(PID:PID On/Off) / 24(PIDC:PID reset) / 26(CAS:Control gain setting) /
27(UP:Remote-controlled accel.) / 28(DWN:Remote-controlled decel.) /
29(UDC:Remote-controlled data clearing) / 31(OPE:Operator control) /
32(SF1:Multispeed bit command(1) / 33(SF2:Multispeed bit command(2) /
34(SF3:Multispeed bit command(3) / 35(SF4:Multispeed bit command(4) /
36(SF5:Multispeed bit command(5) / 37(SF6:Multispeed bit command(6) /
38(SF7:Multispeed bit command(7) / 39(OLR:Overload limit change) /
40(TL:Torque limit enable) / 41(TRQ1:Torque limit selection(1)) /
42(TRQ2:Torque limit selection(2)) / 43(PPI:P/PI selection) / 44(BOK:Brake
confirmation signal) / 45(ORT:Orientation) / 46(LAC: LAD cancel) /
47(PCLR:Positioning deviation reset) / 48(STAT:90-degree pulse-train input phase
difference permission) / 255 (NO:Not selected)
◯
= Allowed
= Not permitted
◯
×
[ ]
= Allowed
= Not permitted
◯
×
[ ]
Alarm relay terminal function
Terminal (13) function
C023