2. In the congur
ation screen, the yellow box shows drive slots that cannot be used.
The number of drive slots appears at Over in Path drive slot count. Drive slots
that have larger drive numbers in the box cannot be used by the number indicated
at Over.
A yellow box appears when there are drive slots that cannot be used in the box. For
these cases, we recommend you do not add the box.
Loading a simple trace when Unit A of a DBX is connected last
If you collect a simple trace le when Unit A of a DBX drive tray is connected last in the
conguration, Unit B of the DBX in the Logical conguration gure and DBX in the
Physical conguration gure are displayed in cyan in the Conguration screen. This
indicates Unit B is not connected because the unit connected last is Unit A of the DBX,
which consists of Unit A and Unit B. You can reference the cable gure where only Unit A
of the DBX is connected.
Procedure
1. In the Array Unit Type dialog box, click Load log to load a simple trace of the
conguration, where Unit A of a DBX is connected last.
After it is loaded, Unit B of the DBX in Logical conguration gure and the DBX in
Physical conguration gure are shown in cyan.
The number of drive slots in Unit B of DBX is not reected in the Array system
drive slot count and Path drive slot count because Unit B of the DBX is not
connected.
2. Click Cable Figure to display the cable gure.
No SAS (ENC) cable is connected to Unit B of the DBX because the Unit A of the DBX
is connected last.
If you collect a simple trace le when Unit A of a DBX drive box is connected last in
the conguration, you cannot click Create on the conguration screen. When the
Logical and Physical conguration gure can be edited, Unit B of a DBX is not
displayed in cyan and Create can be clicked.
Floor load ratings
The oor space at the installation site must support the combined weight of the
following components:
Controller
Drive trays
Rack
All associated equipment
Loading a simple trace when Unit A of a DBX is connected last
Chapter 1: Installation site considerations
Site Preparation Guide for VSP G/F350, G/F370, G/F700, G/F900 39

Other manuals for Hitachi Virtual Storage Platform F350

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hitachi Virtual Storage Platform F350 and is the answer not in the manual?

Hitachi Virtual Storage Platform F350 Specifications

General IconGeneral
BrandHitachi
ModelVirtual Storage Platform F350
CategoryStorage
LanguageEnglish

Related product manuals