EasyManuals Logo

Hitachi Virtual Storage Platform F350 User Manual

Hitachi Virtual Storage Platform F350
106 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #54 background imageLoading...
Page #54 background image
State Controller FMD tray
Operating 50°F to 104°F
(10°C to 40°C)
DKC-F810I-1R6FN/3R2FN/6R4FN/7R0FP/14RFP
drive is installed: 50°F to 104°F (10°C to 40°C)
Non-operating 14°F to 122°F
(-10°C to 50°C)
14°F to 95°F (-10°C to 35°C)
Transport,
storage
-22°F to 140°F
(-30°C to 60°C)
-22°F to 122°F (-30°C to 50°C)
Temperature
change rate
(°C/h)
10°C or less
Humidity
State FMD tray
Operating (%) 8 to 80
Non-operating (%) 8 to 90
Transport, storage (%) 5 to 95
Maximum wet bulb temperature (°C) 29°C (non-condensing)
Vibration
State FMD tray
Operating
(m/s
2
)
2.5 or less (5 to 300Hz)
Within 5 seconds (resonance point: 10 Hz
or less)
Non-operating
(m/s
2
)
5.0 or less at (5 Hz to 300 Hz: no damage
to product)
9.8 (1.0 G): Ensure own safety with fall
prevention.
Within 5 seconds (resonance point: 10 Hz
or less)
Transport (packed)
(m/s
2
)
5.0 m/s or less
Environmental specications
Appendix B: System specications
Hitachi Virtual Storage Platform F700 Hardware Reference Guide 54

Table of Contents

Other manuals for Hitachi Virtual Storage Platform F350

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hitachi Virtual Storage Platform F350 and is the answer not in the manual?

Hitachi Virtual Storage Platform F350 Specifications

General IconGeneral
BrandHitachi
ModelVirtual Storage Platform F350
CategoryStorage
LanguageEnglish

Related product manuals